Installation Instructions for Tachometer
Display Module (TDM) in 4848 Reactor
Controller
555M
Meter installation in 4848 Reactor Controller
1. Unplug the power cord of the 4848 controller. Re-
move the (2) screws located on the top/front cover at
the rear corners of the controller. Gently lift the cover
forward, which is hinged at the bottom, taking care
not to apply tension on any internal wiring.
2. If applicable, remove and discard the black hole
plug on the sloped front panel above the "RPM" text.
This can be done by pinching the clasps on the back
of the plug from the inside of the front plate.
3. Insert the TDM (2084E) through the panel cutout,
from outside in, making sure the rubber gasket is
on the outside of the controller front panel. (If wires
are preinstalled, remove the terminal connector by
releasing the tabs on the sides of the module and
gently pulling the terminal connector off. Reference
photos below.) Slide the white mounting bracket
onto the module with the mounting screws pointing
towards the front panel. Slide the mounting bracket
forward until it touches the controller panel. The
clasps on the mounting bracket should align with the
groves on the module. Gently tighten the screws un-
til the module is held into place. (If removed, reattach
the terminal connector.)
Terminal Connector Removal
Seitenansicht 0
1 2 3 4 5 6 7 8

Inhaltsverzeichnis

Seite 1 - Controller

Installation Instructions for Tachometer Display Module (TDM) in 4848 Reactor Controller555MMeter installation in 4848 Reactor Controller1. Unplug th

Seite 2 - TDM Installation

TDM InstallationParr Instrument Company2Meter Installation Diagram4848 Inside ViewMeter installation in 4848 Reactor Controller (Continued)

Seite 3

TDM Installationwww.parrinst.com3Wiring installation in 4848 Reactor Controller1. If applicable, remove the black hole plug on the back of the contro

Seite 4

TDM InstallationParr Instrument Company4Wiring installation in 4848 Reactor Controller (Continued)4. Attach the 4-pin edge connector from the A2106E

Seite 5

TDM Installationwww.parrinst.com5Wiring installation in 4848 Reactor Controller (Continued)8. Find the remaining black wire #2 from the kit and attac

Seite 6

TDM InstallationParr Instrument Company6Keys command:1. Press “SET” to select 2. Press return key move to next operation mode3. Up/Down arrow keys

Seite 7

TDM Installationwww.parrinst.com7Press “SET” and releaseSelect type/value Select type/value CommentAt OFF Auto Tuning ON/OFFPID0 0 The 0th PID Parame