Parr-instrument Motor Control Module (MCM) Bedienungsanleitung

Stöbern Sie online oder laden Sie Bedienungsanleitung nach Sensoren Parr-instrument Motor Control Module (MCM) herunter. Parr Instrument Motor Control Module (MCM) User Manual Benutzerhandbuch

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 8
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 0
599M
Meter Installation in 4848 Reactor Controller
2100E Black Hole Plug
PLUG
CLASP
Motor Control Module (MCM)
for the 4848 Reactor Controller
Installation Instructions
1. Unplug the power cord of the 4848 controller. Re-
move the (2) screws located on the top/front cover at
the rear corners of the controller. Gently lift the cover
forward, which is hinged at the bottom, taking care
not to apply tension on any internal wiring.
2. If applicable, remove and discard the black hole plug
on the sloped front panel above the "RPM" text. This
can be done by pinching the clasps on the back of the
plug from the inside of the front plate.
3. Insert the MCM (2084E) through the panel cutout,
from outside in, making sure the rubber gasket is
on the outside of the controller front panel. (If wires
are preinstalled, remove the terminal connector by
releasing the tabs on the sides of the module and
gently pulling the terminal connector off. Reference
photos below.) Slide the white mounting bracket
onto the module with the mounting screws pointing
towards the front panel. Slide the mounting bracket
forward until it touches the controller panel. The
clasps on the mounting bracket should align with the
groves on the module. Gently tighten the screws un-
til the module is held into place. (If removed, reattach
the terminal connector.)
Terminal Connector Removal
Seitenansicht 0
1 2 3 4 5 6 7 8

Inhaltsverzeichnis

Seite 1 - Installation Instructions

599MMeter Installation in 4848 Reactor Controller2100E Black Hole PlugPLUGCLASPMotor Control Module (MCM) for the 4848 Reactor ControllerInstallation

Seite 2 - MCM Installation

MCM InstallationParr Instrument Company2Meter Installation in 4848 Reactor Controller (Continued)4. Mount the 1588E Signal Isolator, orient as shown,

Seite 3

MCM Installationwww.parrinst.com3Wiring Installation in 4848 Reactor Controller1. If applicable, remove the black hole plug on the back of the contro

Seite 4

MCM InstallationParr Instrument Company47 8 9 10 11 121 2 3 4 5 62084E Pin Out(Pin 5 is blank)Wiring Installation in 4848 Reactor Controller (Continue

Seite 5

MCM Installationwww.parrinst.com5Wiring Installation in 4848 Reactor Controller (Continued)8. Find the remaining black wire #2 from the kit and attac

Seite 6

MCM InstallationParr Instrument Company6Motor Control Module (MCM) Wiring SchematicP31 - WHITE22 - BLACK3 - WHITE4 - BLACK14 +6 -11 +REMOTEBM10RPM DPM

Seite 7

MCM Installationwww.parrinst.com7Factory Default SettingsMCM ModuleKeys command:1. Press “SET” to select 2. Press return key move to next operation

Seite 8 - 599M R02 Revision 11/08/13

599M R02 Revision 11/08/13

Kommentare zu diesen Handbüchern